Typical Combi Controller
Technical Specification
The specification below is typical of a full specification combi boiler control with user display and diagnostics:-
- 230Vac operation
- 230Vac room thermostat input
- 230Vac Time programmer input (with auxiliary live and neutral terminals to power the clock)
- 230Vac gas valve output (0.5A maximum)
- 230Vac pump output (1A maximum) - optional PWM pump speed control output
- Dc fan interface with PWM speed control output and tacho feedback
- 230Vac 3 way diverter valve output (0.5A change over contacts)
- DHW flow switch input - optional turbine type flow rate input
- DHW overheat safety stat input
- Boiler overheat safety stat input
- Low water pressure safety switch input (or pump flow switch if required)
- DHW NTC thermistor sensor input
- Boiler Flow NTC thermistor sensor input
- Boiler Return NTC thermistor sensor input
- Outside Temperature NTC thermistor input
- User display with 2 x 7 segment LED's
- Boiler Cycles counter
- Hours Run counter
- Faults history records
- Factory settings (with installer or service engineer adjustment if required)
- Lockout reset button
- User CH setpoint potentiometer
- Weather compensation (using outside sensor)
- Multiple Ignition Attempts (5)
Diagnostics facility with optional PC (USB) interface box and Windows™ based diagnostic program.
This is only a small selection of options that are available on request